Catalog Record

Report from S&T Project 23064: Improved Performance During Drought at Glen Canyon

The Glen Canyon machine condition monitoring system provides reliable, accurate diagnostic information of hydropower generator Units 7 and 8. Commissioning confirmed accurate vibration and operational measurements, enabling development of meaningful alarm thresholds. This system was installed to support research into the effects of vortices that form at water intakes during low-reservoir conditions. The system is currently collecting baseline data so that it is prepared to support the study of intake vortex formation, helping assess equipment impacts and operational limits.
Generation Effort S&T Project 23064: Improved Performance During Drought at Glen Canyon
Themes Hydropower
Tags Condition Based Maintenance, Predictive Maintenance
Reclamation Project Colorado River Storage Project
Reclamation Program Science and Technology Program

Location Information

Location Description
Location Tags Upper Colorado River Basin
Location Parent
State(s) Arizona
Unified Region(s) Upper Colorado Basin
Timezone MT
Elevation 3,299 ft
Vertical Datum NAVD88
Coordinates (lat, long) (36.93661409, -111.48387184)
Horizontal Datum WGS84